Scholarly Search Engine

Non rebreathing anesthesia machine

Name

A suspected malignant hyperthermia managed without dantrolene sodium

10 L/min) through a non-rebreathing circuit. The anesthesiamachine was quickly replaced with a machine that had not been exposed to inhalation anesthetic agents. Anesthetic maintenance was changed to a continuous infusion of propofol...

Stars: 88 Updated: September 4th,2018

Islamic Views on Globalization. The assertion of non-western modernities

Abstract BACKGROUND: Bacterial contamination of anesthesiabreathingmachines and their potential hazard for pulmonary infection and cross-infection amo...

Stars: 94 Updated: September 4th,2018

Rebreathing after incorrect assembly of sodalime canisters on Blease Sirius anaesthetic machines

Rebreathing after incorrect assembly of sodalime canisters on Blease Sirius anaesthetic machines.venous gas embolism...Rebreathing after incorrect assembly of soda lime canisters on Blease Sirius anesthesiamachines. Anaesthesia. 2007...

Stars: 125 Updated: September 4th,2018

The ideal oxygen/nitrous oxide fresh gas flow sequence with the Anesthesia Delivery Unit machine ☆

Anesthesia Delivery Unit anesthesiamachine.Study DesignProspective, randomized clinical study.SettingLarge teaching hospital in Belgium.Patients53 ASA physical status I and II patients ...(4)-=- The anaesthetic machine selected fresh...

Stars: 130 Updated: September 4th,2018

Controllable partial rebreathinganesthesia circuit and respiratory assist device

A method and apparatus for administering anesthesia to a patient is shown. A control module may be connected through an inhalation breathing circuit to a patient with a portion of the mixed/expired gases being rebreathed by the patien...

Stars: 104 Updated: September 4th,2018

Perkembangan Sirkuit Anestesi

1,2 Anesthesia circuit, known as the respiratory system is a system that functions to deliver oxygen and anesthetic gases from the anesthesiamachine to a patient who was operated. ...Rebreathinganesthesia circuit and is classified a...

Stars: 38 Updated: September 4th,2018

A novel cause of rebreathing carbon dioxide related to removed CLIC-seal on the Dräger Apollo© anesthesiamachine

A novel cause of rebreathing carbon dioxide related to removed CLIC-seal on the Dräger Apollo© anesthesiamachineWe present a case report involving two sequential, surgically uneventful, laparoscopic cholecystectomies using the same...

Stars: 148 Updated: September 4th,2018

ANESTHESIAREBREATHING APPARATUS

Abstract: A general anesthesiarebreathing system comprised of a disposable portion easily coupled to and decoupled from a permanent portion. The...... A general anesthesiarebreathing system comprised of a disposable portion easily ...

Stars: 40 Updated: September 4th,2018

Modular anesthesia respiratory system

An anesthesia system wherein the respiratory system is fitted with interchangeable patient circuit modules that allows a generic fitting in the machine to have affixed, hereto, a module ...circuit modules easily changed and thus be ad...

Stars: 48 Updated: September 4th,2018

Anesthesiarebreathing apparatus

A general anesthesiarebreathing system comprised of a disposable portion adapted to be easily coupled to and decoupled from a permanent portion. The disposable portion includes conventional breathing tubing for coupling a source of f...

Stars: 40 Updated: September 4th,2018

matched results. Showing page 1 of 5.